logo

JobNob

Your Career. Our Passion.

Electrical Safety


Saaki Argus & Averil Consulting


Location

Chennai | India


Job description

About Client:

Our client is an leading provider of power transmission solutions in India and abroad. We offer endtoend services from design engineering procurement construction commissioning operation and maintenance of power transmission infrastructure. We have executed projects in various terrains and challenging environments including high altitude desert coastal and urban areas. We have also diversified into renewable energy smart grid and digital solutions to cater to the evolving needs of our customers and stakeholders.


Location ; Chennai


Roles & Responsibilities:


Conduct Hazardous area classification study for various Industrial sectors pharma FMCG Petrochemical paint oil and gas and refineries


o HAC study by Point source method Example blanketing and riskbased

o Able to perform calculations and prepare source data sheets in line with various standards. Calculate source extent for various sources of releases.

o Knowledge of International standards IEC 60079 NFPA 497 IP 15 NFPA 499 API 505 and OISD 113

o Selection of equipment and preparation of equipment specification appropriate for the zones

o Handson experience with HAC software Quadvent/Aloha/Phast

o Inspection of Explosionproof equipment according to IEC 60079 will be an added advantage


Perform electrostatic hazard assessment for various industrial operations


o Understanding the flammability ignition sensitivity and electrostatic properties of the gas(es) liquid(s) and dust(s)

o Identifying the charge generation/retention at various stages of the process and review of the existing measures to eliminate and/ or control electrostatic ignition hazards

o Recommendation on practical measures to eliminate and/or control the potential of the static caused fires and/or explosions

o Knowledge of International standards NFPA 77 IECAPI 2003


Conduct Dust Hazard analysis according to NFPA 652 654 standards


o DHA by prescriptive method Risk assessment

o Ability to understand the combustible dust characteristics of the material handled and correlate with the process

o Identify potential ignition sources perform risk assessment documentation of results and provide recommendations to prevent and mitigate potential fire flash fire and explosion hazards.


Conduct ignition risk Assessment for nonelectrical installations according to IECstandards.

Remote Work :

No


Job tags



Salary

All rights reserved